Field Sweeping with the SDA-5000: Test Point Compensation
62
4
Press this soft key to call up the TESTPOINT INFO
screen shown in Fig. 4-4. This screen provides
information for telemetry and sweep about transmitted
output levels, total losses, and actual and desired levels
and the delta between them.
4. To accurately calculate reverse test point loss, its helpful to have a
block diagram of the amplifier to be adjusted. When youre balancing
constant inputs to the hybrid, the Internal entry represents the internal
losses from the injection point to the hybrid. These losses (the top
entry box in the display) arise from the various splitters, diplexers, and
so on, in the amplifier between the injection point and the amplifier
input. Test point, or probe, loss (the entry box third from the top in the
display) is the DC value of the test point.
Fig. 4-2 The REV COMPENSATION Screen
CAUTION ! Resistive test points should not be used for
reverse sweep. You might get inaccurate results because
of the presence of standing waves.
External losses represent the components used to connect to the test
point. For these values, positive numbers represent loss, which is the
norm. Negative values represent gain (a very rare event). This value
is entered in the box second from the top in the display.
Add all test point losses to get a total.