Field Sweeping with the SDA-5000: Considerations for Sweep in the Field
80
4
Limit Screen
The screen shown in Fig. 4-13 is where you set the value for n in the
equation n/10+x, and set the Limit in dB.
NOTE: You set the x in n/10+x from the main SWEEP
menus Sweep Limit Variable option. (See SWEEP Menu
Options on page 67.)
Call up the limit screen from the SWEEP screen (Fig. 4-10) by
pressing the top soft key on the right side of the screen.
Press the soft key next to the Amplifier icon to set the amplifier
number. Use the up and down diamond keys to make the
adjustment.
Use the Limit Set icon to manually edit the limit number in +/-
dB; adjust with the up and down diamond keys.
NOTE: In Loopback mode, the Amplifier and Limit Set
icons do not appear.
NOTE: There should be no need to edit the limit number
because the unit calculates the value automatically.
Fig. 4-13 The SWEEP Limit Screen
The Limit box