Wavetek MS1300 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Měření, testování a kontrola Wavetek MS1300. Wavetek MS1300 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 101
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Wavetek Wandel GoltermannWavetek Wandel Goltermann
Wavetek Wandel GoltermannWavetek Wandel Goltermann
Wavetek Wandel Goltermann
CATV Division
5808 Churchman Bypass
Indianapolis, IN 46203-6109
(800) 851-1198
(317) 788-9351
Fax: (317) 614-8313
Internet: http://www.wavetek.com
11/99 Rev. D
Manual Part No.
6510-00-0416 C
opyright © 1999 Wavetek Wandel Goltermann
This document contains information proprietary to
Wavetek Wandel Goltermann. The information in this document
is not to be used or duplicated in any manner without
the prior approval, in writing, of Wavetek Wandel Goltermann.
OPERATION MANUAL
MODEL CLI-1450
SCANNING SIGNAL LEVEL
& LEAKAGE METER
Zobrazit stránku 0
1 2 3 4 5 6 ... 100 101

Shrnutí obsahu

Strany 1 - MODEL CLI-1450

Wavetek Wandel GoltermannWavetek Wandel GoltermannWavetek Wandel GoltermannWavetek Wandel GoltermannWavetek Wandel GoltermannCATV Division5808 Ch

Strany 2 - WARRANTY

1-4executed immediately or scheduled over a period of time. Toconserve battery life, CLI-1450 shuts itself off between scheduledintervals. When conf

Strany 3 - Contents

E-2115 117.5 120 122.5 125 127.5 130 132.5 135 137.5 1401919.52020.52121.52222.52323.52424.525Len gt hMHZMHZIt is highly recommended that the element

Strany 4

E-3OPERATIONFor normal measurements, connect the connector on the antennaassembly directly to the antenna connection on the Model CLI-1450leakage mete

Strany 5

1-51111122222555553333366666444447777777777

Strany 6

1-6AntennaAntennaAntennaAntennaAntennaPortPortPortPortPortSerial PortSerial PortSerial PortSerial PortSerial PortChargerChargerChargerChargerChar

Strany 7

1-7StealthWare 3.0. Refer to page 1-21 for configuration instructionsand page 2-36 for operating instructionsGETTING ACQUAINTED WITH THE KEYPADThe key

Strany 8 - LEVEL MEASUREMENTS

1-8 NAVIGATOR NAVIGATOR NAVIGATOR NAVIGATOR NAVIGATORInstantly "travel" to any mode using the NAVIGATOR.4.4.4.4.4.

Strany 9

1-9SNAP SHOTSNAP SHOTSNAP SHOTSNAP SHOTSNAP SHOTHold the measurement. The measurement is retained even ifthe cable is disconnected from the input

Strany 10 - REVERSE INGRESS SCAN

1-10Title Bar IndicatorsTitle Bar IndicatorsTitle Bar IndicatorsTitle Bar IndicatorsTitle Bar IndicatorsYou may see indicators appear above

Strany 11

1-11ListsListsListsListsListsLists present several items for viewing and/or selecting. Notice thatthe currently chosen item is highlighted. You can sc

Strany 12

1-12THE NAVIGATORYou can easily travel to any mode using the NAVIGATOR. To accessthe NAVIGATOR, press the key.An icon appears on the screen for each

Strany 13

1-13To configure your CLI-1450, press the SHIFT + keys or choosethe icon from the NAVIGATOR. The following screen appears:Configuration settings a

Strany 14

Wavetek Wandel Goltermann warrants that all Products manufactured or procured by WavetekWandel Goltermann conform to Wavetek Wandel Goltermann's

Strany 15

1-14CONTRAST LEVELCONTRAST LEVELCONTRAST LEVELCONTRAST LEVELCONTRAST LEVELAdjusts the contrast level of the LCD for optimum viewing.Not

Strany 16

1-15turn off automatically. The indicator means that the backlight is onand will remain on continuously. If you see no indicator, the back-light i

Strany 17

1-16LINES/PAGELINES/PAGELINES/PAGELINES/PAGELINES/PAGEFor text reports, you can specify the number of lines that will beprinted on each page before a

Strany 18 - CONFIGURE

1-17Measurement ConfigurationTEMPERATURE UNITSTEMPERATURE UNITSTEMPERATURE UNITSTEMPERATURE UNITSTEMPERATURE UNITSSelects the units in which temp

Strany 19 - Global Configuration

1-18EDIT TEST POINTSEDIT TEST POINTSEDIT TEST POINTSEDIT TEST POINTSEDIT TEST POINTSYour CLI-1450 is capable of performing tests a

Strany 20

1-19You can selectively enable or disable each individual limit. When alimit is disabled, your CLI-1450 excludes it when checking limits. Ifthe highl

Strany 21

1-20Noise Floor CorrectionNoise Floor CorrectionNoise Floor CorrectionNoise Floor CorrectionNoise Floor CorrectionThis calibration measures

Strany 22

1-21Start FrequencyStart FrequencyStart FrequencyStart FrequencyStart FrequencyEnter the start frequency that you want to monitor for reverseingr

Strany 23 - Measurement Configuration

1-22· when the threshold is exceeded· when a tag signal is detected· when the threshold is exceeded and a tag signal is detected· disable the alarmALA

Strany 24

1-23REFERENCE DISTANCEREFERENCE DISTANCEREFERENCE DISTANCEREFERENCE DISTANCEREFERENCE DISTANCEThis is the specified distance at which leakage is

Strany 25

iContentsIntroducing the CLI-1450 ... 1-1Introduction ...

Strany 26

1-24the dipole antenna corresponds to theHD-1 Dipole Antenna that wasshipped with your unit. If you choose to use another type of dipoleantenna, you m

Strany 27 - Leakage Configuration

1-25CHANNEL PLAN CONFIGURATIONWhat is a Channel Plan?A channel plan is a framework of cable network parameters chosen bythe user for his network. T

Strany 28

1-26Using the up/down arrow keys, highlight Channel Plan and then pressto bring up the Configure - Channel Plan screen. This screen lists thevarious i

Strany 29

1-27Select Video Signal TypeHighlight VIDEO SIGNAL TYPE from the Channel Plan screen(page 1-26). Choose from NTSC, PAL and SECAM types.Press .Select C

Strany 30 - Channel Plan Configuration

1-28NOTENOTENOTENOTENOTE: If your system is a PAL M type, select NTSC for your channel plan.Using up or down arrow key, highlight a base channel plan

Strany 31 - CHANNEL PLAN CONFIGURATION

1-29The unit will complete the build and display the Build Channel Plan-STEP 5 screen (shown right above).Press the right softkey to return to the mai

Strany 32 - Select a Channel Plan

1-30IMPORTANTIMPORTANTIMPORTANTIMPORTANTIMPORTANT: You may find an enabled channel that isnot in your channel plan. This should be disabled. A channel

Strany 33 - Select Channel Sequence

1-31TypeTypeTypeTypeTypeThere are three channel types from which to choose:TV -the standard video and audio carriersDUAL -a video carrier with two ind

Strany 34

1-32PackagePackagePackagePackagePackageYou can organize channels into packages. In the edit box,you can select any package that is enabled (see the s

Strany 35 - How to Edit the Channel Plan

1-33How to configure a digital carrierHow to configure a digital carrierHow to configure a digital carrierHow to configure a digital carrierHow to con

Strany 36

iiInstallation Results Summary... 2-9The Channel List ...

Strany 37

1-34Up to six channels can be selected. To select a channel, use the up ordown arrow to highlight the desired channel in the list, then press thesoft

Strany 38

1-35Copy Remote PlanCopy Remote PlanCopy Remote PlanCopy Remote PlanCopy Remote PlanOnce a plan has been created in one unit, it can be copied to anot

Strany 40 - Select Channel Packages

2-1 MODEL CLI-1450INTRODUCTIONThe best way to learn about the CLI-1450 is to use it. Section 2discusses the individual measurements available with th

Strany 41 - Copy Remote Plan

2-2You can read the leakage measurement numerically and on an analogmeter. The units in which leakage is being measured appears directlybelow the met

Strany 42

2-3MEASUREMENT PEAKMEASUREMENT PEAKMEASUREMENT PEAKMEASUREMENT PEAKMEASUREMENT PEAKThe peak leakage value is indicated on the analog meter as a s

Strany 43 - MODEL CLI-1450

2-4NoteNoteNoteNoteNoteThe characteristics for each type of antenna are programmable. Besure that you have enabled all the antenna types that you wan

Strany 44

2-5COMPENSATIONCOMPENSATIONCOMPENSATIONCOMPENSATIONCOMPENSATIONCompensation allows you to adjust your CLI-1450 to a calibrated leakfield (see Appendix

Strany 45

2-6The Find and Fix mode assists the operator in locating the leakagesource through numeric and audible alarm indicators. As your dis-tance from the

Strany 46

2-7PRINTING THE SCREENPRINTING THE SCREENPRINTING THE SCREENPRINTING THE SCREENPRINTING THE SCREENYou can print the entire screen at any tim

Strany 47

iiiScan ... 2-22Moving the Marker ...

Strany 48

2-8Press the key to select the INSTALLATION mode or choosethe icon from the NAVIGATOR. Your CLI-1450 will beginmeasuring all the enabled channels i

Strany 49 - INSTALLATION

2-9Subscriber DropGround BlockTapUser DefinedNoteNoteNoteNoteNoteBe sure that you have enabled all of the test points that you areinterested in using.

Strany 50

2-10NoteNoteNoteNoteNoteOnly the limits that are enabled in the selected test point appear onthis screen. If there are no enabled test points, this sc

Strany 51

2-11THE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORUse the PASS/FAIL ind

Strany 52

2-12This screen displays video and audio carrier level measurementsalong with the DVA for the selected channel. Use the up or downarrows to select th

Strany 53

2-13ADJUSTING THE REFERENCE LEVELADJUSTING THE REFERENCE LEVELADJUSTING THE REFERENCE LEVELADJUSTING THE REFERENCE LEVELADJUSTING THE RE

Strany 54

2-14Use the left and right arrows to tune your CLI-1450. The frequencyincrements or decrements by the step size that you have specified inthe Measurem

Strany 55

2-15WARNING INDICATORSWARNING INDICATORSWARNING INDICATORSWARNING INDICATORSWARNING INDICATORSIf the current measurement is inaccurate due to an

Strany 56

2-16MOVING THE MARKERMOVING THE MARKERMOVING THE MARKERMOVING THE MARKERMOVING THE MARKERA vertical marker appears over the currently select

Strany 57 - FULL SCAN

2-17to zoom in and the soft key to zoom out. The magnificationfactor is displayed above the graph. Press the soft key when youhave finished.CHEC

Strany 58

ivAppendicesAppendix A: Specifications ... A-1Appendix B: Power Management and Battery ...

Strany 59

2-18When you have selected the limits submenu, the marker informationbelow the graph is replaced by the overall limit check summary forchannels curren

Strany 60

2-19Up or down arrows to the left of the video level and DVA numericmeasurement tell you when the limits have been exceeded. measurement too high m

Strany 61

2-20displaying one of the following warning indicators to the left of thenumeric level measurement in the marker information area: Over-rangeThe signa

Strany 62

2-21ImportantImportantImportantImportantImportantYou can choose which carriers appear on this screen when you config-ure your channel plan (see SELECT

Strany 63

2-22MEASUREMENT HOLDMEASUREMENT HOLDMEASUREMENT HOLDMEASUREMENT HOLDMEASUREMENT HOLDYou can freeze the tilt measurement at any time by pressing t

Strany 64

2-23NoteNoteNoteNoteNoteThe channels that appear on this screen are the same ones that youselected when you configured your tilt channels. (see SELECT

Strany 65

2-24NoteNoteNoteNoteNoteBe sure that you have enabled all of the test points that you areinterested in using. The soft key is only available if the

Strany 66

2-25PRINTING THE SCREENPRINTING THE SCREENPRINTING THE SCREENPRINTING THE SCREENPRINTING THE SCREENYou can print the entire screen at any ti

Strany 67 - AUTO TEST

2-26list. Press the soft key to select the highlighted locationand continue to the next step.TipIf you are not interested in logging the informatio

Strany 68

2-27Measure VoltageMeasure VoltageMeasure VoltageMeasure VoltageMeasure VoltageYou can log voltage measurements that you make using yourmultimete

Strany 69

1-1 MODEL CLI-14501Introducingthe CLI-1450INTRODUCTIONThe CLI-1450 Leakage/Signal Level Meter is a high performanceinstrument designed for cable tele

Strany 70

2-28TemperatureTemperatureTemperatureTemperatureTemperatureThe ambient temperature at which the test is performed isrecorded. Your CLI-1450 contains a

Strany 71

2-29If you are performing a scheduled test, the time remaining until thenext interval will appear upon completion of the measurements.ImportantImporta

Strany 72

2-30VIEWTo access measurement files that you have stored in your CLI-1450,choose the icon from the NAVIGATOR. Files are categorizedinto Installatio

Strany 73

2-31To view a file, use the up and down arrows to highlight the name ofthe file that you want to view and then press either the soft keyor the ke

Strany 74

2-32TipTipTipTipTipYou can resave an Installation file by pressing the SHIFT + keys.This allows you to change the name of the file.VIEWING SCAN FIL

Strany 75

2-33NoteNoteNoteNoteNoteYou can print the entire screen at any time by pressing the SHIFT + keys. A bar graph appears indicating the status of the pr

Strany 76

2-34Press the soft key to view information about the Auto Test file.This displays the information that was logged when you configuredthe test. The

Strany 77

2-35The first screen that will appear is a tabular list that includes the videoand audio carrier levels along with the delta V/A for each channel.Use

Strany 78 - INGRESS SCAN

2-36Press the soft key to sequence through the available test points.The test point that you have selected is represented in the upperportion of th

Strany 79

2-37MOVING THE MARKERMOVING THE MARKERMOVING THE MARKERMOVING THE MARKERMOVING THE MARKERA vertical marker appears over the currently select

Strany 80

1-2To reduce the likelihood of false alarms, you can configure the alarmto occur only when a tag signal is present. You can quickly adjust thevolume

Strany 81

2-38THE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORTHE PASS/FAIL INDICATORUse the PASS/FAIL ind

Strany 82 - INFORMATION

3-1 MODEL CLI-1450USING THE REFERENCE SECTIONThis section provides additional information concerning the use ofthe CLI-1450. Items include; Help, Inf

Strany 83 - TECHNICAL SUPPORT

3-2Next to the icon is a brief description of the function that the softkey performs. If an icon is currently inactive "feature not available&quo

Strany 84

3-3TECHNICAL SUPPORTWavetek Wandel Goltermann has worked hard to make the CLI-1450as easy-to-use as possible. However, if you have a problem using you

Strany 86

A-1 MODEL CLI-1450SPECIFICATIONSFrequencyRange: 45 to 559 MHz; 5 to 890 MHz (optional);sub band option (5 to 80 MHz)Accuracy: 20 ppmTuning Resolution

Strany 87

A-2CW Detection: From 0.5 µV (typical)with LT1000 Leakage Tagger activated(121 to 133.2625 MHz)Measurement: From 1.4 µV(115 to 140 MHz)Range: 0.5 to 2

Strany 88

A-3VMA-3: Magnetic mount 1/4 λ whip antenna1019-00-0470: Cloning Cable (RS232 Interconnect cable)1019-00-0558: Charger/Adapter universal input, 1

Strany 90 - Global Configuration section

B-1 MODEL CLI-1450Battery Pack Location and InstallationThe CLI-1450 battery pack (1019-00-0479) is located on the backof the unit. To remove or repl

Strany 91

1-3which channels are active on your cable system. Once you havedefined a channel plan, you can copy it to other units. You can alsocreate channel p

Strany 92 - CABLE SPECIFICATIONS

B-2To maximize battery life, set Auto Shutoff to 1 minute and Back-light Shutoff to "always off". These items are described in theGlobal Con

Strany 93

C-1 MODEL CLI-1450CONNECTORThe CLI-1450 has a serial interface with RS232 drive, using a 3-pinstereo connector. The serial interface has a driver bui

Strany 94

C-2CABLE SPECIFICATIONSCLI-1450 TO PC (1019-00-0469)CLI-1450 TO PRINTER (STANDARD) (1019-00-0468)

Strany 95

C-3CLI-1450 TO CLI-1450 (1019-00-0470)CLI-1450 TO PRINTER (CITIZEN) (1019-00-0467)

Strany 97 - CALIBRATION

D-1 MODEL CLI-1450INTRODUCTIONRegardless of the type of vehicle-mounted antenna used, severalvariables come into play that could cause a change in m

Strany 98

D-2SETUPThe frequency and level of the predictable “leak” should be givencareful consideration, to avoid interfering with any off-air service orallowi

Strany 99

D-3b. Source antenna should be carefully located to isolate it fromsources of reflection.c. Source antenna should be properly polarized (vertical, ifv

Strany 100 - Antenna Cutting Curve

D-4ImportantYour CLI-1450 stores a separate compensation value for eachantenna type. The value automatically becomes effective when youselect the ant

Strany 101 - CARE AND MAINTENANCE

E-1 MODEL CLI-1450INTRODUCTIONThe VMA-3 Quarterwave Antenna is a field tunable antennadesigned to perform leakage measurements when used with theWWG

Komentáře k této Příručce