5.2.6 Select Sweep Direction
There are two possible sweep directions on units with the Reverse
Sweep Option; Forward and Reverse. Use the edit box to select the
desired direction, and press the ENTER key.
Note: When sweeping, the direction may be changed by simply
pressing the left arrow key for reverse, or the right arrow key for
forward sweeping.
If the 3SRV is setup for multiple user operation with a 3HRV, reverse
sweeping is performed with the 3HRV, forward sweeping is performed
with the 3ST.
5.2.7 Adjust the Reverse Telemetry Level
This is the level of the carrier that the 3SR uses to transmit telemetry
data. Use the edit box to set the Reverse Telemetry Level to an
appropriate value. When adjusting the Reverse Telemetry Level,
take into consideration the following losses; system, summing
network, test point, and amplifier desired input.
NOTE: The frequency of the reverse telemetry carrier is set on the
3ST/3HRV. There is no adjustment for the Reverse Telem-
etry Frequency on the 3SR.
5.2.8 Adjust the Reverse Sweep Insertion Level
This is the level at which the 3SR inserts (transmits) sweep points.
All sweep points are inserted at the same level. Use the edit box to
set the Reverse Sweep Insertion Level to an appropriate value (This
will typically be at maximum (+50 dBmV) to over come test point
loss.).
NOTE: The frequencies at which the sweep points are inserted are
defined in the Reverse Sweep Plan which is set on the 3ST/
3HRV. The frequency of the sweep points cannot be ad-
justed on the 3SR.